Blue Mountain Commercial 30kW HV Hybrid Inverter
R 35,205.09
Blue Mountain Commercial 30kW HV Hybrid Inverter
The BME 30kW boasts of other features such as
Pure sine wave output.
Self-consumption and Feed-in to the grid.
Programmable supply priority for PV, Battery or Grid.
True galvanic isolation transformer design.
User-adjustable charging current.
Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup.
Built-in timer for various mode of on/off operation.
Multiple communication for USB, RS-232, Modbus and SNMP.
Monitoring software for real-time status display and control.
Parallel operation up to 4 units only for 30KW.
Specifications
Maximum pv input power: 45Kw.
Rated output power: 30Kw.
Maximum charging power: 30Kw.
Grid-tie operation
Pv input (DC)
Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 950 VDC.
Start-up Voltage / Initial Feeding Voltage: 500 VDC / 550 VDC.
MPP Voltage Range: 460 VDC ~ 900 VDC.
Full power MPP Voltage Range: 625 VDC ~ 900 VDC.
Number of MPP Trackers / Maximum Input Current: 1 / 72A.
Grid output (AC)
Nominal Output Voltage: 230 VAC* (P-N) / 400 VAC (P-P).
Output Voltage Range: 195.5 – 253 VAC per phase.
Output Frequency Range: 49 ~ 51 Hz or 59.3 ~ 60.5 Hz.
Nominal Output Current: 43.5 A per phase.
Power Factor > 1.0.
Efficiency
Maximum Conversion Efficiency (DC/AC): 95%.
Off-grid operation
AC Input
AC Start-up Voltage/Auto Restart Voltage: 150 – 170 VAC per phase / 180 VAC per phase.
Acceptable Input Voltage Range: 170 – 280 VAC per phase.
Maximum AC Input Current: 43.5 A per phase.
Pv input (DC)
Maximum DC Power / Maximum DC Voltage: 30Kw / 950 VDC.
MPP Voltage Range: 460 VDC ~ 900 VDC.
Number of MPP Trackers / Maximum Input Current 1 / 72 A.
Battery mode output (AC)
Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P).
Output Waveform: Pure Sinewave.
Efficiency (DC to AC): >91%.
Hybrid operation
Pv input (DC)
Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 950 VDC.
Start-up Voltage / Initial Feeding Voltage: 500 VDC / 550 VDC.
MPP Voltage Range: 550 VDC ~ 900 VDC.
Number of MPP Trackers / Maximum Input Current 1 / 72 A.
Grid output (AC)
Nominal Output Voltage: 230 VAC* (P-N) / 400 VAC (P-P).
Output Voltage Range: 184 – 265 VAC per phase.
Output Frequency Range: 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz.
Nominal Output Current: 43.5 A per phase.
Power Factor: > 1.0.
AC Input
AC Start-up Voltage / Auto Restart Voltage: 120 – 140 VAC per phase / 180 VAC per phase.
Acceptable Input Voltage Range: 170 – 280 VAC per phase.
Maximum AC Input Current: 40 A per phase.
Battery mode output (AC)
Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P).
Efficiency (DC to AC): >91%.
Battery & charger
Nominal Battery Voltage/Charging Voltage Range: 384 VDC/384-480 VDC.
Maximum Charging Current: 80A.
General
Physical
Dimension, D x W x H (mm): 430 x 715 x 1021.
Net Weight (kgs): 223.
Interface
Communication Port: RS-232/USB.
Intelligent Slot Optional SNMP, GPRS, WIFI, Modbus cards available.
Environment
Humidity: 0 ~ 90% RH (Non-Condensing).
Operating Temperature: -10 to 55°C.
Altitude: 0 ~ 1000 m**.
Important:
All solar products, power systems, water heating and gas products and their components must be installed by appropriately qualified personnel. All installations must adhere to local wiring regulations and standards.
Important:
All solar products, power systems, water heating and gas products and their components must be installed by appropriately qualified personnel. All installations must adhere to local wiring regulations and standards. Solar Power Space Online will not be held liable for any product malfunctions as a result of incorrectly installed systems.
Reviews